    <title language="eng">Axial Flow Fan Design Parameter Affecting the Performance</title>

    <authors>
	 


      <author>
       <name>Ankesh Kumar Pataskar, </name>

 
		

	<affiliationId>1</affiliationId>
      </author>
    


	 


      <author>
       <name>V.N. Bartaria</name>


		

	<affiliationId>1</affiliationId>

      </author>
    


	 


      <author>
       <name>Abhishek Jain</name>

		

	<affiliationId>1</affiliationId>
      </author>
    


	



	



	

    </authors>
    
	    <affiliationsList>
	    
		

		<affiliationName affiliationId="1">University Institute of Technology, Barkatullah University, Bhopal, India.Lakshmi Narayan College of Technology, University Institute of Technology, Barkatullah University, Bhopal, India.</affiliationName>
    


		

		

		

		

		

	  </affiliationsList>







    <abstract language="eng"><p>Axial flow fans are employed in heat exchangers and other engineering systems where the flow path around the fan becomes like a duct. The flow takes place along the axis of rotation of the rotor. The flow is essentially symmetrical to the axis. The design calculations are performed with presumption of flow through cascade of blade and it is the main governing factor of the design too. In this paper procedural calculation for an axial flow fan with profiled blade are presented. Calculations are tabulated for different parameter of radius and angles. On profiling, the increase of outlet angle has been shown which gives ultimate angle opening. The small corrections are therefore obtained. Different parameters used in the design are tabulated to get the calculation more accurately.</p></abstract>
